This one-day class will feature presentations & training on Fire Protection Air Supply Decisions and Corrosion Mitigation Technology for Dry & Pre-Action Fire Sprinkler Systems. These presentations are presented by one of the top leaders in the Dry Pipe Fire Sprinkler System Industry and offers 4 NICET CPD credits.
6991 Peachtree Industrial Blvd.
Peachtree Corners, GA 30092
Building 400
Field Technicians
Fire Protection / Design Engineers
Authorities Having Jurisdiction
Insurance Providers
Service Managers
Installation Managers
Project Managers
Facility Managers
Service Technicians
Installation Technician
Inspectors
Simplifying corrosion prevention in Dry & Pre-Action Fire Sprinkler Systems. Vapor Pipe Shield is a patented, UL Listed Vapor phase Corrosion Inhibitor delivery system that is fully mechanical and piped directly in line between the air compressor and the Dry System valve, making corrosion prevention efficient, easy to install and maintain, and highly cost effective.
The most advanced Fire Protection Air Compressors ever built - The Advance Series Compressors feature a UL 508 Listed, General Air Products Digital Pressure Switch. Our Digital Switch not only makes installation a breeze, but is also a very powerful troubleshooting tool.
Understand the components of an antifreeze listing and how and why listings (like minimum pressure requirements and maximum volume allowances) differ among listed solutions
Gain insight into the requirements for antifreeze systems per NFPA 13/13R/13D
Learn the changes related to antifreeze systems published in the 2023 Edition of NFPA 25
Recognize the best practices and tools needed to design, install, test, and maintain a system with a listed antifreeze and how they may differ from those of a non-listed solution
The types of chemicals that can affect performance, and where they commonly come from
Tips and free resources to ensure compatibility from the start of a job and beyond
How to use the FBC™ System Compatible program website and mobile app
Leaks due to corrosion and flooding caused by frozen auxiliary drains in a fire sprinkler system can cause severe property damage and leave a facility susceptible to fire. These common issues are preventable, and recent additions to NFPA 13 code have been adopted to address these concerns.
New K28 ESFR with UL specific application listings to increase storage capacity in new and existing warehouses.
New P frame for K22 & K25 ESFRs which provide the smallest take out in the industry especially when utilized with our new FM approved guard and shield assembly which meets the FM criteria when utilizing ESFR Pend’s for in rack storage systems.
And the LB11, which is the industries only HSW sprinkler for storage applications, and the industries first sprinkler for Lithium-Ion Battery Storage.
Overview of Backflow Preventers will include where and why they are used, maintenance & repair requirements, flow performance & system design, and their impact on sprinkler system performance.
Discussion on types of Pressure Regulation devices, the importance of understanding static and residual pressures, and NFPA-13 / NFPA-25 testing requirements.
Covering hybrid suppression systems and some of the updates to both the technology and software, which lowers the barrier of entry to suppression applications for the Fire Sprinkler Contractor, making it more accessible than ever.
ASC Engineered Solutions new Flexhead releases are now available! The innovator of the flexible drop, Flexhead offers tool less installation, increased installation speed, and cost savings in design.
An overview of fire pump control panels and starting methods, installation best practices and general operation of the HMI.
This Class will go over the basics of pump room layouts. Types of fire pump systems, Fire Pump Accessories. We will focus on best practices for installation, look at some of the do’s and don’ts for installation.Reasons why we do not do certain things and basic NFPA and NEC Electrical Requirements for fire pumps.
A leading distributor serving the fire protection industry; Core & Main understands the importance of providing quality products and services to our customers. Backed by vast resources, large inventories and state-of-the-art fabrication facilities, their many branches across the U.S. are there to serve you; and remain committed to complete customer satisfaction.
10:00 AM – 12:00 PM – Fire Protection Air Supply Decisions - Choosing the Right Air Supply for Your Dry or Pre-action System
Ray Fremont Jr – President, General Air Products
There are a variety of technologies on the market for filling dry pipe and pre-action fire sprinkler systems - namely compressed air, dry air, nitrogen, and vapor corrosion inhibitors. Different projects require different types of air supply equipment, and each technology comes with its own benefits and drawbacks. Some might be surprised to know that no one type is the best fit for every application!
In this session, we will review the available technologies, examine the pros and cons of each type, and discuss corrosion mitigation from both a design and field-level perspective. Additionally, we will provide attendees with a series of in-depth questions designed to help you decide if a particular air supply technology is the right fit for a given application.
10:00 AM – 12:00 PM – Fire Protection Air Supply Decisions - Choosing the Right Air Supply for Your Dry or Pre-action System
Ray Fremont Jr – President, General Air Products
There are a variety of technologies on the market for filling dry pipe and pre-action fire sprinkler systems - namely compressed air, dry air, nitrogen, and vapor corrosion inhibitors. Different projects require different types of air supply equipment, and each technology comes with its own benefits and drawbacks. Some might be surprised to know that no one type is the best fit for every application!
In this session, we will review the available technologies, examine the pros and cons of each type, and discuss corrosion mitigation from both a design and field-level perspective. Additionally, we will provide attendees with a series of in-depth questions designed to help you decide if a particular air supply technology is the right fit for a given application.
1:00 PM – 3:00 PM – New Corrosion Prevention Technology For Dry and Pre-action Fire Sprinkler Systems
Ray Fremont Jr – President, General Air Products
Introducing the Vapor Pipe Shield Corrosion Inhibitor Delivery System for Dry & Pre-Action Fire Sprinkler Systems & General Air’s new Advance Series Compressors, featuring our patented Digital Pressure Switch.
Providing a deep-dive into Vapor Corrosion Inhibitor technology, its efficacy & safety, and how the UL-Listed Vapor Pipe Shield delivery method allows for their use in Dry & Pre-Action Fire Sprinkler Systems.